PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE FOODSERVICE.PENTAIR.COM | 17
FLUSH BUFFER TANK (CONTINUED) CONNECT TO EQUIPMENT
9. Let ATM ll until tank is full. ATM tank system status
light turns from blue to green.
10. Repeat Steps 6 through 8 for nal ush of ATM tank.
ADJUST BLENDING VALVE
11. Adjust blending valve during ATM tank lling to TDS
levels per desired settings. Review TDS levels from
digital TDS meter.
12. Adjust values plus or minus on the blend valve.
Monitor consistency when set.
13. Let the tank ll completely with the set optimized
water. ATM tank system status light turns from blue
to green.
CONNECT TO EQUIPMENT
14. Connect end of outlet tubing to equipment.
If garden hose connection is not required –
use alternate connection to ½" ID tubing (not
included).
If using garden hose tting to ½" hose, secure
with clamp.
a. Separate the hose barb adapter into three parts:
threaded tting, barbed ange, gasket. Slide band
clamp onto hose rst and threaded tting second.
b. Insert barbed ange into hose.
c. Push until edge of ange is ush with hose tip.
d. Insert gasket into threaded tting.
e. Slide band clamp to end of hose and tighten screw.
15. Open outlet valve on RO processor to allow
optimized water to enter equipment.
Water will begin to enter equipment.
Complete nal check for leaks.
Reinstall ATM tank cover and 6" access lid.
SYSTEM INSTALL AND FLUSHING COMPLETE.
Treated water is in use at equipment.
It may take several hours to completely ll the
tank and fully pressurize the system. Make sure to
check for leaks when fully pressurized.
NOTE: The blended water tubing/piping and associated
ttings connecting the RO blended water outlet to
the equipment being serviced should be food-grade
material that meets NSF® Standard 51, 61, or similar,
with a minimum pressure rating of 100 psi (6.9 bar,
0.69 MPa). The RO/blended water may react with
metal piping, creating a corrosive condition in addition
to imparting an objectionable taste. Plastic pipe or
reinforced beverage tubing are generally very good
material choices for RO water distribution piping. The
size of the blended water tubing/piping should be
1/2-inch (12.7 mm) O.D. minimum.
9
13
1211
B
D
E
10
7
6 8
B
A
14
C
CONNECT TO EQUIPMENT
ADJUST BLENDING
FLUSH
FLUSH
15

Bekijk gratis de handleiding van Everpure EZ-RO 375, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkEverpure
ModelEZ-RO 375
CategorieNiet gecategoriseerd
TaalNederlands
Grootte13630 MB