16 | PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE FOODSERVICE.PENTAIR.COM
ATM TANK FILL AND PUMP STARTUP (CONTINUED)
12. Let ATM tank ll until tank is full. ATM tank system
status light turns from blue to green.
• System status solid green indicates ATM tank is
full and high-level sensor is met.
NOTE: If water does not stop and system status does
not turn green, check high level sensor connection.
See troubleshooting guide.
FLUSH BUFFER TANK
1. Unplug tank power supply.
2. Slowly open outlet valve on RO processor to begin to
drain buffer tank water through gray hose attached
to sink. When ow rate from the outlet hose stops,
buffer tank is empty.
3. Close outlet valve on RO processor when buffer tank
is empty.
NOTE: Steps 2 and 3 can alternatively be completed
using the ATM TANK OUTLET VALVE.
4. Connect power supply to wall outlet. Pump should
begin to run and ll buffer tank as in step 11 on
previous page.
5. REPEAT STEPS, 1 through 4 a total of 5 times to
ush buffer tank. After 5th time ushing buffer tank,
move to step 6.
6. Open outlet valve on RO Processor to allow water
to drain from ATM tank completely. Pump will be
running water this entire time.
7. Pump should shut down when tank is near empty or
low-level sensor has been exposed. System status
light should be yellow. Drain buffer tank to empty
also – water ow from optimized outlet will come to
near stop.
NOTE: Water will be lling the ATM tank From the RO
processor at this time. This is expected.
• Once low-level sensor sees water again, the system
status light will turn to blinking yellow indicating
that the pump is on delay for ve minutes.
8. Close outlet valve on RO processor to allow ATM
Tank to continue to ll.
• Water will be lling ATM tank from ATM TANK INLET
• ATM tank system status will indicate low level –
once water meets low level switch – pump delay
will begin with ashing yellow light. (Pump delay is
ve minutes.)
• Pump will begin to cycle to ll ATM buffer tank and
will probably cause low level situation repeatedly
until ATM tank Outlet line pressurizes to 70 to
60 psi. This is normal. Fill ATM tank full. System
status will indicate a solid green light and drain
ow/to tank water ow will stop.
12
1
2
6
3
5
Empty , Fill Empty , Fill 1.1.
Empty , Fill Empty , Fill 2.2.
Empty , Fill Empty , Fill 3.3.
Empty , Fill Empty , Fill 4.4.
Empty , Fill Empty , Fill 5.5.
4
8
7
FLUSH