Eventide BD600+ handleiding
Handleiding
Je bekijkt pagina 47 van 64

RS232 Command Set
BD600+ Profanity Delay Appendix C RS232 Control Page 43
Document Version 2.3
G go to next config variable steps to next config variable. Responds with normal !>. Use X to request cur-
rent config variable name and value. See also C, E, N, Q, V, X, and Y com-
mands.
H go to static at current delay cancels a rebuild or ramp to zero.
I enter panic mode
J set delay followed by a numerical delay value terminated by a space or <return>. No
more than one second is allowed to elapse between characters, and no charac-
ters apart from 0-9 and decimal point and space characters are allowed. If the
unit is in MPD mode this command sets the MPD time, otherwise the delay
cannot exceed the current DLAY value.
When not in MPD mode, the DLAY value can instead be temporarily set by this
command by terminating the value by an asterisk, e.g. J57.5*. This will last un-
til the unit next starts or enters bypass, at which point the DLAY value will be
restored to the configured value.
K ends a sneeze or mute or station break
L requests levels three-character response is left channel level followed by right channel level
and terminated with >. Levels are reported using one digit ASCII hex of range
0 through 9, and A. Example: 25> is left channel level of 2, right channel of 5.
M requests mode response is three characters of the form m!> where m is the current mode.
Modes are A <wait and exit>, B <bypass>, H <static>, I <panic>, L <live>, M
<mute>, P <micro precision delay>, R <rebuild>, S <sneeze>, W <wait for
safe>, Z <ramp to zero>.
note: zero delay and maximum delay are not modes; if the unit reaches maxi-
mum delay while in rebuild, it switches to static mode, while if it reaches zero
delay while in ramp to zero, it switches to live mode.
N next config value sets the current config variable to the next value. When the maximum value is
reached, the next will be the minimum. Responds with normal "!>". Can only
be used in bypass mode. Use X to request current config variable name and
value. See also G command.
P requests MPD delay value response is 8-digit (including decimal point) ASCII value of delay in millisec-
onds, followed by position indicator (1, 2, 3, 4, 5 or 6), followed by >. Note:
This does not change the mode to MPD. Example: if delay is 1.1 seconds and
the 4
th
digit is selected, the response will be “1100.0004>”.
Q resets config stepping points at start of configuration mode. Used with C, E, G, N and V, X, and Y
commands to make configuration changes to the BD600+.
R initiates rebuild
S starts a sneeze see K command for end-sneeze.
T requests current delay response is 4-digit decimal ASCII value of delay in 10s of milliseconds, fol-
lowed by >. The BD600+ can be configured to automatically send delay values
whenever they change by use of the SEND configuration variable.
U requests current delay as hex sends delay amount in 10s of milliseconds as hexadecimal using 4 chars of
ASCII hex followed by H>.
V Eventide Factory Defaults sets factory defaults for all config variables (except baud rate). System must be
in bypass.
Bekijk gratis de handleiding van Eventide BD600+, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Eventide |
Model | BD600+ |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 3523 MB |