RS232 Command Set
Page 42 Appendix C RS232 Control BD600+ Profanity Delay
Document Version 2.3
0 requests static at 0 delay puts the unit in-line. If the unit was in BYPASS and the RUN variable specifies
MPD or MPD1-4, MPD mode will be entered, using the selected delay. Otherwise
the unit will enter profanity delay mode at zero delay (live).
1 increments MPD digit note: MPD must be entered via configuration change to the run mode parame-
ter.
2 decrements MPD digit
3 selects MPD digit
5 starts mute use the K command to un-mute. Works in MPD and profanity delay modes.
The system will continue whatever it was doing before, but the output will be
silent. Mute will be cancelled on entering BYPASS.
4 not used
6 initiates or cancels station
break insert see page 35 for information on the Station Break Insert feature.
7 initiates ramp to bypass performs ramp to zero and then automatically switches to bypass.
8 initiates wait for bypass performs wait and exit and then automatically switches to bypass.
9 not used
@ go to MPD initial character must be followed within 1 second by one of 0 to 4 - will enter
MPD mode using either current MPD value (value 0), or MPD value 1 to 4
(value 1,2,3 or 4). This will last until the next bypass, after which the unit will
return to its configured mode.
A initiates wait and exit
B switches to bypass mode
C requests config values shows the current settings of each of the config values. This long response in-
cludes multiple records, each consisting of a 4 byte config variable name, fol-
lowed by an ASCII equal sign (=), followed by a 4 byte config value, followed
by hex 0D,0A (carriage return, line feed). The last record will be followed by a
>. None of the 4 byte values contain >. The records correspond to configuration
variables described in Chapter 3 and consist of ASCII characters of the set 0
through 9, A through Z, space and dash. Records will be padded with trailing
spaces where necessary to bring them up to 4 bytes.
D performs a dump note: this command will NOT drive RLA1 or RLA2, even if configured for
DUMP.
E entire config table dump entire config table with all variables and all available values. This long
response includes multiple records, each consisting of a 4 byte config variable
name, followed by an ASCII equal sign (=), followed by one or more 4 byte
strings, each containing config values, separated by spaces, followed by a space
and then hex 0D,0A (carriage return, line feed). The last record will be fol-
lowed by a >. None of the 4 byte values contain >. The records correspond to
configuration variables described in Chapter 3 and consist of ASCII characters
of the set 0 through 9, A through Z, space and dash. Records will be padded
with trailing spaces where necessary to bring them up to 4 bytes. Note that the
REB values will depend on the current DLAY value.
F go to static at full delay if the RUN variable does not specify MPD, the unit goes to in-line, static and at
full delay.