Eventide BD600+ handleiding
Handleiding
Je bekijkt pagina 25 van 64

Chapter 3 Configuration
BD600+ Profanity Delay Chapter 3 Configuration Page 21
Document Version 2.3
There are a number of adjustable values used by the BD600+. Configuration mode gives access to
these values and allows them to be changed. This chapter covers the configurable variables for the
basic BD600+. Configuration of optional features is covered in the appendices.
The configuration mode is operated by the front panel buttons, which are used to navigate through a
map of configuration variables. The WAIT FOR SAFE and WAIT AND EXIT buttons are used to
move left and right across the map. The REBUILD and RAMP TO ZERO buttons are used to adjust
the values of individual variables. The CONFIG button will move to the left side of the map and, if
pressed while already on the left side, will move up through the levels. The SNEEZE button is used to
reset a selected variable to the factory default.
See the side-bar for a partial map of the configuration parameters. Complete information is provided
in a following table. This map is a combination of the maps for both the BD600+ and BD600E+.
Basic Operation Example
From bypass mode, press CONFIG. The display
changes to show CONF. Press CONFIG again to move up
the map. The first press will move to 1 ON. The next will
move to 2 TI. Now press the WAIT AND EXIT button a
few times to move over to the REBvariable (rebuild
time). Notice that the SNEEZE button's LED is not lit.
This means that the REB variable is set to the factory de-
fault. Use the RAMP TO ZERO button to change the
value. Notice that the SNEEZE button lights up. Press
the SNEEZE button to reset the parameter back to fac-
tory default.
Another Example
If the BYPASS button is not illuminated, press
BYPASS. Next, press CONFIG. Once the display
shows CONF, press the RAMP TO ZERO button. The
display changes to 1 ON.
Now press the WAIT AND EXIT button once.
The display changes to RUN. To check the run mode,
press the REBUILD or RAMP TO ZERO button. The
display changes to show LIVE, indicating “go into live
mode when exiting from bypass.” To change the run mode, press the RAMP TO ZERO button. Use the
REBUILD and RAMP TO ZERO buttons to go up and down through the four possible values for the
run parameter.
Press BYPASS to exit from configuration mode and return to bypass mode. Any changes made will
remain until they are reconfigured.
Password Protection
If desired, configuration mode may be password protected. The display will then show P--- when the
CONFIG button is pressed. To enter configuration mode, the user must first press and hold the
CONFIG button, then a single other button (password) and then release the CONFIG button. Pressing
the wrong button will return the unit to bypass mode. This procedure has been made deliberately ob-
scure to ensure authorized use. Change or disable the password button using the PASS configuration
variable. => See page 30 for more information.
6EXT ⇒ BAUD ⇒ BITS ⇒ PARI ⇒
⇑
5REMote ⇒ AUX1 ⇒ AUX2 ⇒
AUX3 ⇒
AUX4 ⇒
⇑
4PROcessing
⇒
THRS
⇒
TMP0
⇒
SRCE
⇑
3 AUdio ⇒ INPT ⇒ SYNC
⇒
FLBK
⇒ IN G
⇑
2 TIme
⇒
DLAY
⇒
REB
⇒
SAFE
⇒
DUMP
⇒
⇑
1 ONline ⇒RUN ⇒POWP⇒BYP⇒
⇑
CONF (config)
⇑
(bypass)
Bekijk gratis de handleiding van Eventide BD600+, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Eventide |
Model | BD600+ |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 3523 MB |