Eventide BD600+ handleiding
Handleiding
Je bekijkt pagina 23 van 64

Operation as a Micro Precision Fixed Delay
BD600+Profanity Delay Chapter 2 Operation Page 19
Document Version 2.3
The BD600+ may be used as a fixed stereo delay line, adjustable from 0.010 seconds to 19.999999
seconds, adjustable in microseconds (0.000001 seconds) or thousandths of film/video frames. Opera-
tion is straightforward, with several front panel buttons serving secondary duty as fixed delay controls.
There are two ways to enter precision delay mode – the first method is from configuration mode. Go
into bypass mode.
• In bypass mode the display shows .
• Press the CONFIG button. This puts the unit into configuration mode (display shows CONF).
• Now press the CONFIG button again. You are now at the "on-line" configuration level (display
shows 1 ON).
• Now press the WAIT AND EXIT button. The display should now show RUN.
• Now press the RAMP TO ZERO button repetitively (stepping through run options) until the dis-
play shows MPD.
• Press the BYPASS button to exit configuration mode. The display should show .
• Now press BYPASS to put the unit in-line. The unit will be in micro precision delay mode.
To return to profanity delay operation, press BYPASS, then CONFIG twice, then WAIT AND EXIT.
The display now shows RUN. Now press SNEEZE to return to the factory default setting of the run pa-
rameter. Now press BYPASS to get out of configuration mode.
The second way to enter precision delay mode is to select MPD as the maximum delay time (DLAY).
Then the maximum delay is determined by the fixed delay settings, and normal broadcast delay func-
tions may be used to enter and exit precision delay mode. For example, if you REBUILD to maximum,
once the fixed delay value is reached the unit will enter precision delay mode. RAMP TO ZERO or
WAIT AND EXIT may be used to return to profanity delay functionality. In this mode, the fixed delay
value becomes the SAFE value, and the DUMP button illuminates when it is reached.
Controlling the Fixed Delay
In precision delay mode the profanity delay buttons have their normal functions for delay values of
100mS and above. Below 100mS they are inactive. This allows you to ramp up to or down from the
precision delay time, which now becomes the SAFE value.
There is one addition – the CONFIG button is also active. If CONFIG is selected it will flash, and the
meanings of the buttons change to allow the fixed delay value to be changed. In this mode, the only
operable buttons are BYPASS, WAIT FOR SAFE, WAIT AND EXIT, REBUILD, DUMP and RAMP
TO ZERO. The buttons behave as follows:
• BYPASS takes the unit off-line. Always valid.
• WAIT FOR SAFE selects the digit to the left. Valid if lit.
• WAIT AND EXIT selects the digit to the right. Valid if lit.
• REBUILD decrements selected delay digit. Valid if lit.
• RAMP TO ZERO increments selected delay digit. Valid if lit.
• DUMP sets the delay to its minimum value (10mS).
Bekijk gratis de handleiding van Eventide BD600+, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Eventide |
Model | BD600+ |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 3523 MB |