00156502, Version 1.1
25/28
Interconnecting several devices (master/slave operation)
Several devices may be interconnected (max. 32). Then all slave units can be synchronized and controlled
with the master unit without the need for a DMX controller. The devices must be set to the corresponding
operating modes.
1 Configure all slave units before connecting the master unit: Press the MENU button so many times until
Addr is indicated in the display. Confirm with the ENTER button.
2 Connect the DMX output of the master unit to the DMX input of the first slave unit. Then connect the
DMX output of the first slave unit to the DMX input of the second slave unit, etc. until all units have been
connected in a chain. Make sure the master unit is the first in the chain. Do not connect a DMX controller
to the DMX input of the master unit.
3 Set the master unit to the desired operating mode, Auto, SoUn or manual Mode (MAun). The
interconnected devices will now operate synchronously
DMX operation
Setting the number of DMX channels and the DMX starting address
For operation with a controller with DMX512 protocol, the device is equipped with 5 control channels. To be
able to operate the device with a DMX controller, the DMX starting address must be set for the first DMX
channel. The starting address depends upon which DMX controller is being used. Please refer to the
controller’s documentation.
1 Press the MENU button so many times until Addr is indicated in the display. Confirm with the ENTER
button.
2 Now the display indicates the menu item for the DMX starting address A001. Use the buttons UP and
DOWN to set the address. Confirm with the ENTER button.
3 The display indicates Chnd. Confirm with the ENTER button. The display indicates Ch05 (5 DMX
channels). Confirm with the ENTER button.
4 A dot will blink when DMX signals are being received. If no control signals are available, the display will
blink.
Note: Please make sure that you do not have any overlapping channels in order to control each device
correctly and independently from any other fixture on the DMX chain. If several devices are addressed
similarly, they will work synchronically.
Color wheel
Open
Red
Green
Blue
Yellow
Cyan