PROBLEM CAUSE SOLUTION
The error message
E2“ will be
displayed.
The room temperature sensor
failed or is damaged.
If repair is necessary, please
contact automatized service.
The error message
E3“ will be
displayed.
The sensor of the pipeline
of the vaporizer failed or is
damaged.
If repair is necessary, please
contact automatized service.
The error message
E4“ will be
displayed.
The container for condensate
is full.
Drain water from the container.
If this message appears
frequently even if the container
is not evidently full, contact the
service center.
The error message
E5“ will be
displayed.
The sensor of condensate failed
or is damaged.
If repair is necessary, please
contact automatized service.
VIII. TECHNICAL DATA
Cooling capacity (Btu/h)/(W) 9000 Btu/h/2600 W
Capacity of dehumidication (l/h) 1,15 l/h
Electric input at cooling 950 W/4,3 A
Air power (m
3
/h) 350 m
3
/h
Voltage / frequency (V/Hz) 220V-240V~ / 50Hz
Noisiness (dB(A)) L
PA
≤54 db(A)
L
WA
≤65 db(A)
Energy E󰀩ciency Ratio (EER) 2,6
Potential of global warming (kg CO
2
) 3
Class of EER A
Weight (kg) 26 kg
Dimensions (WxDxH); mm unit 415 x 300 x 670 mm
package 475 x 360 x 880 mm
Coolant R290
Maximum quantity of coolant 185 g
Discharge Side Pressure 2,5 Mpa
Suction Side Pressure 1,2 Mpa
E󰀨ective for a room with a volume of about 30-40 m
2
Current fuse 3. 15A 250 V; 5xL20 mm
Electric input in standby mode < 0,50 W
Appliance with protection class I.
GB
32 / 65