Usage
1. Press the SURVEY button (8) to enter the menu. Press the Left/– button (3) or the Right/+ button (9) to select the stud
detection mode.
2. Complete the calibration and place the device flat against the surface to be tested.
3. Slowly move the detector across the surface in the direction you want to scan.
4. The blue line is displayed on the screen during the search for wooden/metal objects. If a stud is detected, the screen will
display the wooden/metal stud icon , the value of the distance to the target, and the signal strength indication. The device
emits a sound. The closer the device to the object, the stronger the signal.
AC detection mode
This mode is used only to detect live wires.
Calibration
1. Press the SURVEY button (8) to enter the menu. Press the Right/+ button (9) twice to select the AC detection mode.
2. Place the device flat against the target surface.
3. Press the MEAS button (7) to start calibration. The calibration will be carried out automatically. When the white part of the
display becomes dark, the calibration is completed.
4. Remove the device from the surface and press Power/Back button (4) to exit the calibration mode.
Usage
1. Complete the calibration and place the device flat against the surface to be tested.
2. Slowly move the detector across the surface in the direction you want to scan.
3. When the device detects a live wire, the screen will display the live wire icon , the value of the distance to the target, and
the signal strength indication. The device emits a sound. The closer the device is to the object, the stronger the signal will be.
You can reduce the sensitivity of the device multiple times to narrow the search area even more and locate the live wire with
greater accuracy.
Specifications
Laser class class II, 630–670nm, < 1mW
Units of measurement m/ft/in/ft + in
Measurement range 0.2–40m
Measuring accuracy ±1.5mm
Pythagoras function +
Area measurement +
Volume measurement +
Triangle area measurement +
Trapezoid measurement +
Horizontal line measurement +
Vertical line measurement +
Countdown measurement +
Digital level scanning angle ±90°
Max. detection depth
live wiring: 50mm
ferrous metals: 120mm / non-ferrous metals: 100mm
wood/metal studs: 38mm
Display 2.4" HD color screen, 240x320px resolution
Sound alert +
Auto-off 3 min.
History records 50 groups
Operating temperature range
0... +40°C (operating), –10… +60°C (storage) /
+32... +104°F (operating), +32… +104°F (storage)
Power source rechargeable lithium battery (500mA·h)
Dimensions 63x25x139mm
Weight 146g
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care and maintenance
Do not touch the sensing area of the device during measurement in order to avoid mistakes, because the human body has
conducting properties. Do not exclusively rely on the detector to locate items behind scanned surfaces. Do not assume that
there is no live cabling inside a wall. Always use caution when nailing, cutting, or drilling in walls, floors, and ceilings that may
contain live cabling. Calibrate the device regularly following a routine schedule.
This is a class II laser product. Please DO NOT stare into the beam, with unprotected eyes or through an optical device, at any
time or direct it towards other people. Do not remove any safety labels. Do not aim the device directly at the sun. Do not try to