Config Menu
Use the Config menu to set the following output conditions for the output signal:
•Signal Muteselect the condition for muting the output signal to
No Muting, Mute On Noise, or Freeze on Noise.
•Analog Setupset to On if setup is present on the analog input, or Off if
no setup is present.
•V Blankingset the vertical blanking to Narrow (NTSC: lines 1-9,
PAL: lines 1-6) or Wide (NTSC: lines 1-20, PAL: lines 1-22).
•Comb Modeset the comb filtering to Comb On or Comb Off.
•Peak Indicatorselects the amount of headroom used in determining
peak indication. Chose Clipping, 2 dB Headroom, 4 dB Headroom,
6 dB Headroom, 8 dB Headroom, or 10 dB Headroom.
•Dig Ref Levelselects the digital reference output level. Choose -20 dBFS or
-18 dBFS.
•Anlg Ref Levelselects the analog audio input level for embedding.
Choose -10 dBu or +4 dBu