Handleiding
Je bekijkt pagina 24 van 37

User Manual: Interactive Digital Signage
SW601990 Rev K, Page 24 of 37
Thermal Protection Mode icon will show on the top corner of these menus indicating that the
Thermal Protect Mode is active
The user will be prompted to shut off the monitor within sixty seconds if the temperature
continues to rise after Thermal Protection Mode Step 2 has been enabled. If the system is not
manually turned off in sixty seconds, the touchmonitor will automatically turn off to prevent
permanent damage to the monitor. The table below shows the Auto Shut Off temperature.
Note: This will only enable in extreme conditions.
Portrait and Landscape Mode
Monitor Size
Thermal
Protection
Mode (°C) Step
1
Thermal
Protection
Mode (°C) Step
2
Auto Shut Off
Temperature (°C)
ET32/4201L 60 65 70
ET5501L 56 61 65
ET7001L/ET7001LT 50 55 63
In the event that Thermal Protection Mode Step 1 or 2 has been enabled, the monitor will
resume full operational capabilities after the OSD temperature decreases to the values set forth
in the table below. These temperatures must be retained for at least five minutes.
Bekijk gratis de handleiding van ELO 4201L, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | ELO |
| Model | 4201L |
| Categorie | Monitor |
| Taal | Nederlands |
| Grootte | 4431 MB |
Caratteristiche Prodotto
| Kleur van het product | Zwart |
| Gewicht | 22200 g |
| Breedte | 955 mm |
| Diepte | 77.7 mm |
| Hoogte | 588 mm |







