18
Bypass screw
Valve
Determining t
he Minimum Flame
Position
To determine the minimum position, ignite
the burners and leave them on in the
minimum position. Remove the knobs to
gain access to the screws. With the help of
a small screwdriver, fasten or loosen the
bypass screw by around 90 degrees. When
the flame has a length of at least 5/32 "
(4 mm), the gas is well distributed. Make
sure that the flame does not die out when
passing from the maximum position to the
minimum position. Create an artificial wind
with your hand towards the flame to see if
the flames are stable. For the oven burner,
operate the oven burner at the minimum
position for 5 minutes, then open and close
the oven door 2-3 times to check the flame
stability of the burner.
Bypass screw
Thermostatic oven valve
2.5 eleCtriCal ConneCtion anD Safety
WARNING: The electrical connection
of this appliance should be carried out
by an authorized service person or
qualified electrician, according to the
instructions in this guide and in compliance
with the current local regulations.
WARNING: THE APPLIANCE MUST
BE EARTHED.
Before connecting the appliance to the
power supply, the voltage rating of the
appliance (stamped on the appliance
identification plate)
must be checked for
correspondence to the available main
supply voltage, and the main electric
wiring should be capable of handling the
appliance’s power rating (also indicated
on the identification plate).
During installation, please ensure
that isolated cables are used. An
incorrect connection could damage your
appliance. If the maincable is damaged
and needs to be replaced this should be
done by a qualified person.
Do not use adaptors, multiple sockets
and/or extension leads.
The supply cord should be kept away
from hot parts of the appliance and must
not be bent or compressed. Otherwise
the cord may be damaged, causing a
short circuit.
If the appliance is not connected
to the main with a plug, a all-pole
disconnector (with at least 1/8 " (3 mm)
contact spacing) must be used in order
to meet the safety regulations.
The appliance is designed for a power
supply of 110-120 V. If your supply is
different, contact the authorized service
personnel or qualified electrician.
The power cable must be long enough
to be connected to the appliance.
The fused switch must be easily
accessible once the appliance has been
installed.
Ensure all connections are adequately
tightened.
Fix the supply cable in the cable clamp
and then close the cover.
The terminal box connection is placed
on the terminal box.
CAUTION: Risk of Electric Shock. If
the cord or plug becomes damaged,
disconnect the appliance from the
power supply and replace only with a
cord or plug of the same type.
Brown
Yellow+Green
Blue