1004
The machine is adjusted at the plant to be suitable for the kind of gas specified on the order.
If you have to supply your machine with gas in a family different from the gas for which your
machine was adjusted, proceed as follows.
Testing pressures
According to the EN 437 standard, the values of the testing pressures mentioned in our
various documents are values for static pressure taken at the gas inlet connection of the
machine ; the heating of the machine being on.
Changing to a gas in the same family (type H or L)
• Change the injector and its joint and if necessary do the air adjustment (see tables of
correspondences).
Changing to a gas in a different
family (from type H or L to
propane)
• Change the injector and its joint (see
tables of correspondences).
• Unscrews the fixing screws (V) and
remove the adjusting head (J) as well
as its cork (T), keep these parts in
case a change would by necessary.
• Replace it by the cork (L) and the plate
(P).
• Screw the two screws and block.
Changing a gas from one family to
another (from propane to type H or
L)
• Change the injector and its joint (see
tables of correspondences).
• Unscrews the fixing screws (V) and
remove the plate (P) as well as the
cork (L), keep these parts in case a change would by necessary.
• Set the cork (T) and the adjustment head (J).
• Screw the two screws and block.
6. Installation/
Putting into service