Electrolux EUD-630CV handleiding
Handleiding
Je bekijkt pagina 21 van 52

Installation manual
21
4.3 Siting
Install the machine close to a floor drain or open drain.
The machine should be positioned so that there is plenty of room for working, both for the user and service personnel.
The figure shows minimum distance to a wall and/or other machines. Failure to respect the prescribed distances will
prevent easy access for maintenance and service operations.
A A
B
fig.X00959
A 25 mm / 1 inch
B 500 mm / 20 inch
4.4 Mechanical installation
If the machine is not to be mounted on a base the machine must be fastened to the floor with the enclosed expansion
bolts.
The table shows the correct position of feet and drilling points.
EUD-615, EUD-618, EUD-625: Mark and drill two holes (⌀ 8 mm / 5/16 inch) about 40 mm / 1 9/16 inch deep in posi-
tion (1).
EUD-630, EUD-645, EUD-660, EUD-680: Mark and drill two holes (⌀ 10 mm / 3/8 inch) about 50 mm / 1 15/16 inch
deep in position (1).
C A
D
G
F
E
B
H
FRONT
= drilling points
= position of feet
1
1
X
X
X-X
fig.5989C