TROUBLESHOOTING
Do not repair or disassemble the air condioning. Unqualied repair will invalidate the
warranty and may lead to failure, causing injuries and property damage. Only use it as directed
in this user manual and only perform operaons advised here.
Problems
Reasons
Solutions
The air conditioner
does not work.
There is no electricity.
Please turn it on after connecting it to a socket
with electricity.
The display shows "E4".
Discharge the water inside.
The ambient temperature is too low or too high.
Only use the machine within a temperature
range of 7-35
0
c (44-95°F).
In cooling mode, the room temperature is lower
than the desired temperature.
Change the desired temperature.
In dry mode, the ambient temperature is low.
The ambient temperature must be above
17 °c. (62 °F).
The cooling effect
is not good.
There is direct sunlight.
Use curtains to reduce the direct sun heat.
Doors or windows are open; there are a lot of
people; or in cooling mode, there are other
sources of heat (e.g. fridges)
Close doors and windows; increase air
conditioning power
The filter screen is dirty.
Clean or replace the filter screen.
The air inlet or outlet is blocked.
Clear obstructions: make sure venting is correct
as described in this user manual and the hose is
not bent
Loud Noise
The air conditioning is not placed on a flat
surface.
Put the air conditioning in a flat, hard place (to
reduce noise).
The compressor does
not work.
Overheat protection starts.
Wait 3 minutes until the temperature is lowered,
then restart the machine.
The remote control
does not work.
The distance between the machine and the
remote control is too far.
Let the remote control get close to the air
conditioner and ensure that the remote control
directly faces the receiver.
The remote control is not aligned with the
receiver.
Batteries are dead.
Replace batteries.
Others
No refrigerant or there is minimal refrigerant.
Refer to Service Centre (check leakage, wielding,
vacuum pump, charge refrigerant according to
nameplate)
Anti-freezing protection
Waiting for defrosting.
The function will recover automatically. No user
input is needed.
High-pressure protection.
After the inside gas pressure comes down, it will
function normally. No user input is needed.
If problems not listed in the table occur or recommended soluons do not work, please get in touch
with the service centre.
1.
Has the unit been standing upright for at least 2 hours?
2.
Is the unit plugged into the mains?
3.
Is the fuse OK?
4.
Switch the unit o and wait three minutes to see if the issue is resolved.
Restart the unit.
5.
Check if the water tank is full.