The water
pump is not
working
• Blocked water pipe
• Prolonged use without water
damaged the pump
• Scale buildup on the pump
shaft
• Clean the water pipe with a small brush
• Replace damaged water pump
• Disassemble the shaft, clean debris,
lubricate, and reassemble
No dust
removal
• Honeycomb filter is clogged
Air inlet is blocked
• Remove and clean the filter
• Clear any obstructions from the air inlet
Odour from
unit
• Normal with new units
• Mould or bacterial growth on
the filter
• No action needed – odour fades within
a week
• Clean filter with mild antibacterial
solution and dry thoroughly
Drain valve
leaking
• Faulty valve
• Rubber seal is missing or
dislodged
• Replace the drain valve
• Refit or replace the rubber seal
Please contact customer support if the above solutions do not resolve the problem.
TECHNICAL SPECIFICATION
MODEL
Arctic55ER
DIMENSIONS
520x350x1125mm
WEIGHT
10.5kg
RATED VOLTAGE
220V
RATED FREQUENCY
50Hz
RATED POWER
180W
FUSE SIZE
3A
TANK CAPACITY
50.5L
electriQ UK SUPPORT
www.electriQ.co.uk/support
Please, for your own convenience, make these simple checks before calling the service
line.
If the unit still fails to operate, call 0330 390 3061 or complete the online form.
1. Is the unit plugged into the mains?
2. Is the fuse OK?
3. Switch the unit off and wait three minutes to see if the issue is resolved. Restart the
unit.
Office hours: 9 AM - 5 PM, Monday to Friday
www.electriQ.co.uk
Unit 2A, Trident Business Park,
Neptune Way, Leeds Road,
Huddersfield, HD2 1UA

Bekijk gratis de handleiding van ElectriQ Arctic55ER, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkElectriQ
ModelArctic55ER
CategorieAirco
TaalNederlands
Grootte2443 MB