30 | ELCO GmbH
Assembly
Operation manual 50.0 | Status 10.2021
5.3.11 Checking the connections
Once the assembly process is complete, the following
points must be checked:
B Leak-tightness of all lines.
B Flexibility of all lines to the generation unit.
B Tight fit of all connections in the control cabinet.
B No damage, kinks or pinches in the cabling and
lines.
B The siphon of the condensate drain is filled with
water.
B Tension-free installation of all lines to the generation
unit.
B Clockwise rotating field.
A Check the system.
If the exhaust air and flue gas are extracted together:
A Ensure that the system is fitted with a suitable
exhaust air kit.
If the exhaust air or flue gas is extracted in combination
with another heat source (peak load boiler or another
system):
A Ensure that the system is fitted with a suitable
backflow preventer.
Following assembly, the commissioning of the system
can be arranged with the manufacturer (or a specialist
partner authorised by the manufacturer).
Commissioning request.
Download forms:
Ј
www.elco.net
A Arrange a time and date for the commissioning.