Waterfall 250™ Operation
Stand Alone:
This function is used when using only one unit or running more
than one unit as individual fixtures. See page 10 for detailed info of
dipswitch traits.
A. Set dipswitch 10 to the “On” position.
B. Plug the unit in, the unit will react to sound via an internal
microphone.
C. Use the audio sensitivity knob on the rear of the unit to make the
unit more or less sensitive to sound. Turning the knob in a clock-
wise direction will make the unit more sensitive to sound.
Master / Slave Operation:
This function will allow you to link up to 4 units together. In this mode,
the units will react to sound via the master units’ internal microphone.
The units will run to the built in programs of the unit functioning as
the master.
A. Use XLR cables to daisy chain the fixtures together. Remembering
the female XLR is the output, and the male XLR is the input.
B. Be sure to follow the dipswitch chart on page 9.
C. For longer cable runs, we suggest a terminator at the last fixture in
the cable run (see terminator on page 7).
Universal DMX Control:
This function allows you to use a universal DMX controller such as
the LSC® Show Designer 2.™ The use of a DMX controller will allow
you to customize the operation of the fixture allowing you to have
independent control of the color wheel and the ability to black out the
lamp. This will allow you to create your own programs or use your fix-
tures as textured color changers.
A. The Waterfall 250™
is a three channel DMX fixture.
B. When using a DMX controller and setting up for DMX operation
follow the standard DMX Binary Code for a three (3) channel unit.
Channel 1 is color, channel 2 is glass wheel 1, and channel 3 is
glass wheel 2.
C. For help running in DMX mode consult the manual that came
with your DMX controller.
D. For longer cable runs we suggest a terminator at the last fixture
(see terminator on page 7).
©Elation Professional® - www.elationlighting.com - Waterfall 250™Instruction Manual Page 7 ©Elation Professional® - www.elationlighting.com - Waterfall 250™Instruction Manual Page 8
Waterfall 250™ Set Up
Notice: Be sure to follow gures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield
conductor to come in contact with the XLR’s outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
DMX512 IN
3-PIN XLR
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and
avoids signal transmission problem
s
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
1
2
3
1
2
3
DMX +
DMX -
COMMON
DMX512 OUT
3-PIN XLR
Figure 2
1 Ground
1 Ground
XLR Male Socket
XLR Pin Conguration
3 Hot
2 Cold
2 Cold
3 Hot
XLR Female Socket
Pin 3 = Data True (positive)
Pin 2 = Data Compliment (negative)
Pin 1 = Ground
Special Note: Line Termination.
When longer cable runs are used,
you should use a terminator pin on the last unit to avoid erratic behav-
ior. A terminator is a 90-120 ohm 1/4 watt resistor which is connected
between pins 2 and 3 of a male XLR connector (DATA + and DATA -).
This pin is inserted in the female XLR connector of the last unit in your
daisy chain to terminate the line. Using a cable terminator (ADJ part
number Z-DMX/T) will decrease the possibilities of erratic behavior.
DMX512 IN
3-PIN XLR
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and
avoids signal transmission problems
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
1
2
3
1
2
3
DMX +
DMX -
COMMON
DMX512 OUT
3-PIN XLR
Figure 4
5-Pin XLR DMX Connectors.
Some manufactures use 5-pin XLR
connectors for DATA transmission in place of 3-pin. 5-pin XLR xtures
may be implemented in a 3-pin XLR DMX line. When inserting standard
5-pin XLR connectors in to a 3-pin line, a cable adaptor must be used,
these adaptors are readily available at most professional sound and
lighting stores. The chart below details a proper cable conversion.
Conductor 5-Pin XLR Male (In)3-Pin XLR Female (Out)
Pin 1
Pin 5 - Do Not Use
Pin 4 - Do Not Use
Pin 3
Pin 2
Pin 1
Pin 3
Pin 2
Not Used
Not Used
Data True (+ signal)
Data Compliment (- signal)
Ground/Shield
3-Pin XLR to 5-Pin XLR Conversion
Figure 3
Bekijk gratis de handleiding van Elation Waterfall 250, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Elation |
| Model | Waterfall 250 |
| Categorie | Verlichting |
| Taal | Nederlands |
| Grootte | 1511 MB |