- 16 -
recharging, maintenance and replacing. Before operation carefully read
instruction manuals including operation manual, replenishment preparation and
recharging requirements.
4.4.2 Fire Prevention Measures
Never smoke or use open fire when perform operations on the accumulator. The
accumulator should be away from flammable material at least two meters when
storage or recharging. The location for accumulator storage should be well
ventilated and equipped with firefighting devices.
4.4.3Maintenance of the Accumulator
1) Keep the nuts on every battery cell dry and clean. Tighten every terminal
and cable end and brush them with grease to prevent corrosion. Naked cable
ends and terminal posts should be covered with a skid-proof insulating cover.
2) Every two cells should be well-connected. Check the nuts on each pole, if
loose, tighten the nuts.
3) Keep the surfaces of accumulator clean and dry. After the completion of
recharging, clean spilled acid with cotton yarns or brush. And clean with wet
towel if necessary.
4) Over recharging and over discharging should be avoided, and fast charging
and insufficient recharging are also not allowed. Otherwise life span of the
accumulator may be affected.
5) Do not put conductive objects including metal tools on the accumulator, or
short circuit or even explosion may be caused.
6) Never spill any hazardous liquid or solid material on surfaces of the
accumulator. When using a densimeter or a thermometer, make sure the surface
is clean and clear.
7) Recharge the discharged accumulator in time. Delayed recharging may
damage the accumulator. Do not delay recharging more than 24 hours.
Recharging of the accumulator may not work outdoors in cold weather. In this
case, move it indoors to perform recharging.
8) If the accumulator will not be in use for a long time, it should be recharged
and discharged once every month and it should be fully recharged every time.
9) During recharging or using, the liquid level of electrolyte lowers because of
water evaporation, so pure water should be added. It is not allowed to add
electrolyte with a specific weight of 1.280.
10) If individual cell fails, identify the cause and repair the cell immediately.