Trouble Shooting
Problem Cause Remedy
Motor doesn’t start No electricity - Check electrical outlet
- Check mains cable
Piezo doesn’t ignite Electrode incorrectly adjusted Check electrode and precisely
set according to diagram
No gas at burner - Gas valve is closed - Open valve
- Gas cylinder is empty - New gas cylinder
- Gas hose or connection leaks - Locate point of leak with soap
- foam and repair
Burner ignites, flame is - The thermoelement was not - Repeat ignition procedure
extinguished as soon as the gas - warm enough - while pressing in the gas
valve is released - The safety thermostat - valve knob
--switches off - Allow the heater to cool for a
- few minutes and reignite
Burner goes out while in use - Gas flow too high - Have the pressure regulator
- Air input too low - inspected and replace if
- necessary
- Check the suction grid and
- clean
- Inspect ventilator
Important!
Have repairs carried out only by specialist workshops or ISC.
Technical Data
HGG 120 NIRO HGG 200 NIRO HGG 300 NIRO
HGG 120 NIRO CH
Nominal heat load Qu: Max. (Hs) 12 kW max. (Hs) 20 kW max. (Hs) 30 kW
Air throughput: 500 m
3
/h 500 m
3
/h 500 m
3
/h
Connection: G 30: 1,17 kg/h P/B G 31:1,43 kg/h G 31: 2,15 kg/h
Type of gas: commercially available commercially available commercially available
propane (DIN 51622) propane (DIN 51622) propane (DIN 51622)
Commercially available
butane (DIN 51622)
Operating pressure P: 300 m bar 1,5 bar 1,5 bar
Mains power supply: 230 V ~ 50 Hz 38 W 230 V ~ 50 Hz 38 W 230 V ~ 50 Hz 38 W
Tested in accordance with DIN-DVGW
Made in Germany