6.2. Technical data for sizing the chimney system Sense 8
Quantity
SENSE 8
Rated power
Reduced power
CO
2
7
5,3
%
Smoke temperature at exhaust
209
105
°C
Minimum draught
0,01
Pa
Flue gas flow rate
8,8
3,7
g/s
6.3. Electrical data Sense 8
Quantity
SENSE 8
Power supply
230
Vac
Frequency
50
Hz
Rated power consumption
60
W
Reduced power consumption
33
W
Power consumption in stand-by
3
W
Rated electrical power
90
W
Protection
Fuse 4 AT,250 Vac 5x20
The chimney system and the installation as a whole must comply with the instructions given
in this manual and with all local and national regulations. The installer is responsible for the
installation
The installation must comply with national and local regulations. For safety reasons, the
electrical system must comply with legal standards. Correct earthing is essential.