Use and maintenance manual - Model: “UNICA 10 V/C”
28
ENGLISH
13
PHASE LIST
PHASE DESCRIPTION
- The phase starts to pre-heat the re
sistor and the pellet starts to
fall in the brazier.
- The pellet switches on by taking ad
vantage of the heat in the inlet air
which passes by the duct of the
incandescent resistor.
- Pellet loading restarts and the
ame develops.
The appliance has terminated the
switch on phase and
goes to the working power set.
The desired ambient temperature is
reached.
The cleaning phase is enabled of
the brazier without movement of the
cleaner (periodic function).
The brazier cleaning phase is running
with the cleaner enabled. The
appliance switches off and switches
back on autonomously.
Switch on is required after a cooling
phase.
Once reached this condition,
the appliance restarts automatically.
The appliance is in the switch off
phase and the cooling
phase has not yet
terminated.
The appliance is OFF and all the
motors are disabled.
SWITCH ON
WORK
SAVING
BRAZIER CLEANING
CLEANER ENABLED
FINAL CLEANING
OFF
WAITING FLAME
FLAME PHASE
RESTART
PHASE DESCRIPTION
Room settings is on MAN; therefore
the appliance will only work with
the replace power as per settings
(never switching to saving mode)
MAN OP.
14
FUNCTION LIST
Edit the data highlighted using the keys
Conrm the data changed using the key
Repeat the same operation to set the following
parameter;
OK
12.6
DISPLAY CANALIZATION STATUS
To display the canalization status, from the STAND-BY
status, press the key .
The display screen follows:
SET RH
CHANNELLED
ROOM
TEMP. RH CHAN-
NELLED ROOM
RH VENTILATION
SPEED
When the POWERFUL function is enabled, in display
status, you can also see that channelling is in this
mode, as in the gure below.
Conrm your settings for the RH channelling, press
and repeat the same sequence of operations for
the LH channelling.
OK
Edit the data highlighted using the keys
Conrm the data changed using the key
Repeat the same operation to set the following
parameter;
To return to the STAND-BY screen, use the
key , conrming all the settings.
OK
OK
SET LH
CHANNELLED
ROOM
TEMP. LH
CHANNELLED
ROOM
LH VENTILATION
SPEED
Room temperature for the canalization system can
only be managed if the TEMPERATURE CONTROL
function is enabled, as previously seen, and ENABLE
T.EXT in MANAGE SETTINGS disabled in the CANALI-
ZATION menu.