Use and maintenance manual - Model: “UNICA 10 V/C”
26
ENGLISH
OPERATING PROCEDURE:
MENU >> USER SETTINGS >> CANALIZATION
Access the menu by pressing key
Scroll the items to USER SETTINGS with the key
Access the menu by pressing key
First item in the “CANALIZATION” menu, key
The screen appears with setting of channelling,
as in the gure.
OK
OK
OK
OK
Conrm with key
If the PS function is not set, the fan
is always restricted by the power of
the product.
- SET
MANUAL:
allows you to edit the canalization
power, keys:
0 - ventilation disabled;
1-7 - setting range;
PS - ventilation follows
power to the replace
set on the appliance.
- ENABLE
TEMPERATURE
CONTROL:
enables modulation of the
ventilation once the set values
have been reached;
OK
Enable/disable with the key
-- MANAGE
SETTINGS:
allows you to edit the room tem-
perature you want to reach in
the room where the canalization
system has been installed.
Pressing the keys
to enable/disable the
ag if you want to man-
age the temperature of
the zone to channel with
the help of the external
thermostat.
(not supplied). Key to
conrm.
Press the keys
to set the
temperature of the
zone to channel with
the help of an optional
ambient probe,
provided on request of
Nobis s.r.l.
(not supplies as standard)
OK
If the ag is enabled for “channelling” temperature
management with the external thermostat, it is not
possible to change the temperature setting from the
handheld device, but rather from the external ther-
mostat.
12.2
PROGRAMMED CANALIZATION
In the THERMOSTAT TIMER menu, for models with
channelling, you can set the channelling power
(ventilation speed) and the temperature you want to
obtain in the room where the ventilation outlet
is installed. Having set all the values relating to
programmed switch on of the appliance, the
following screen appears.
Setting the ambient temperature for
channelling, this is only managed if the TEMPERA-
TURE CONTROL function is enabled, previously seen,
ENABLE T.EXT in MANAGE SETTINGS disabled in the
CANALIZATION menu.
Edit the data highlighted using the keys
Conrm the data changed using the key
Repeat the same operation to set the next param-
eter;
To return to the STAND-BY screen, use the
key , conrming all the settings.
OK
OK
12.3
DISPLAY CANALIZATION STATUS
To display the channelling status, from the STAND-BY
status, press the key .
The display screen follows:
CHANNELLED
ROOM
SET
TEMPERATURE
TEMP.
CHANNELLED
ROOM
VENTILATION
SPEED
OR
OK