Use and maintenance manual, model “LIBERA 8 V/C - LIBERA 11 V/C”
ENGLISH
25
reduced to a value which is lower than P1.
At this point, a series of clarications is necessary
to explain how you can benet from the AUTO
function switch to eco mode and/or return to
standard operation:
• The ventilation system, if present and active, works
at different speeds, depending on the difference
between the temperature which has been set
on the remote control and the actual room
temperature as detected by the room probe;
• The appliance gradually increases the hearth’s
power as soon as room temperature drops
below the set value (optimization of combustion/
consumption and acoustic comfort).
10.4 COMFORT CLIMA
As described in the "saving mode" paragraph,
the appliance aims to satisfy the user thermal
comfort. Also, if the building has a good energy
class, this function ensures fuel savings thanks to
the automated switch-on/off.
Below you can nd the instructions to activate the
function and how to make adjustments, followed
by a practical example.
OPERATING PROCEDURE:
menu > user settings > comfort clima
Press OK to access the menu.
Scroll the items up to USER SETTING, key ↓
Press OK to access the menu.
Scroll the items up to COMFORT CLIMA, key ↓
Press OK to access the menu.
The cursor is positioned on the line that allows the
activation and deactivation of the function (key
OK).
In case of reactivation of the function settings
previously programmed according to your
preferences, just press OK and then ← to conrm
and return to the menu.
Press ↓ to move to the second line, where you can
choose the minutes in which the appliance will work
in modulation - ECO - to ensure that the desired
room temperature is reached before turning off. Use
the ↑↓ keys to change the value, then press OK to
conrm.
The value default setting is 4 minutes; you can
choose from 0 (zero) - immediate switch-off - to 9
minutes.
The cursor will move to line 3, where you can choose
the temperature difference (with respect to the
Comfort temperature chosen), below which you
want the product to switch back on. The default
value is -3°C; you can reach up to a temperature
difference of -5°C.
Press ↑↓ to make changes and OK to conrm. Once
the choice has been conrmed, the remote control
will return to the menu screen.
You can wait for the remote control to turn off or just
press ← repeatedly to return to the Stand-by screen.
It is recommended to choose at least 2 °C,
preferably 3 °C, degrees of difference to turn
the product back on. We remind you that the
room probe is located inside the remote control.
Therefore, do not leave it near the stove or near a
door or window, where possible sudden changes
in temperature would cause the product to switch
back on sooner than necessary.
When switched off in COMFORT CLIMA mode, the
remote control will display the following:
When switched back on again in COMFORT CLIMA
mode, the remote control will display the following:
PRACTICAL EXAMPLE:
desired temperature (room settings): 21 °C;
minutes in eco mode: 3;
temperature difference needed to restart: -2°C
(compared to 21°C).
When the temperature detected by the remote
control reaches 21°C, after 3 minutes in eco mode,