7
5.3. Remote Control GPO Ports
WPaBT has 1 NO/NC (normally open/normally closed) relay output on its rear panel.
This output’s change of status is associated with the detection of active A2DP audio
connections. This makes it possible for it to interact with external equipment, such as
motors for projection screens or movable partitions, lights, sirens, GPI inputs from other
equipment, etc.
5.4. eMCONTROL1 connection
WPaBT can provide a remote audio input for a HUB device, using it in combination with
eMCONTROL1. Additionally, an external power supply is not required, as power is
supplied by the HUB device via eMCONTROL1.
Figure 2: WPaBT + eMCONTROL1 connection diagram
Note: Either LEFT or RIGHT outputs can be connected. Ensure that the output is set to
mono using the Ecler Bluetooth® Manager configuration application.
Note: As regards the maximum distances for the CAT5 or higher cabling that connects
an eMCONTROL1 to a HUB unit, these are determined by the AWG category of the cable
used. Examples:
AWG24 cable
AWG23 cable
AWG22 cable
WPaBT
Maximum length 270
metres
Maximum length 340
metres
Maximum length 425
metres
WPaBT +
eMCONTROL1
Maximum length 85
metres
Maximum length 105
metres
Maximum length 130
metres