8
PRECAUTIONS
PACKAGE
CONTENTS
DESCRIPTION
&
FEATURES
INSTALL
&
CONNECT
START-UP
&
OPERATION
PANEL
FUNCTIONS
TECHNICAL
DATA
4.2 NETWORK REQUIREMENTS AND CONFIGURATION
VEO-XTI1CG2 and VEO-XRI1CG2 are not limited to certain brands of network hardware,
but the network must support the following network features:
Layer 3 managed network switch.
IGMP snooping support.
To prevent malfunctioning, interference or drop in signal performance due to other
network products bandwidth requirements or network design. It is highly recommended to
check with the chosen network IT staff how to properly set the Multicast products
connected to the local network switch.
4.2.1 SETTING THE IP ADDRESS
The default IP address is “auto IP” in the range 169.254.10.x for the transmitters and
169.254.20.x for the receivers. It can also be dynamically assigned by the VEO-XCTRLG2
controller in case it is present in the network. For further details please refer to VEO-
XCTRLG2 controller module user manual.
It’s possible to check the assigned IP address from a transmitter or receiver pressing
and holding the (UP button) on the front panel. For further details, refer to
Additional functionalities of CH select / buttons for both: VEO-XTI1CG2 & VEO-
XRI1CG2 chapter.
The IP address can be changed using the embedded web page of a transmitter or
a receiver. Both the network configuration of PC and VEO devices must be in the
same network domain in order to be able to access its web settings page through an
internet browser. For further details, refer to Configuration using Web interface
chapter.
When static IP addresses are required, the IP address of each device needs to be
set manually.