7. OUTPUTS
The SAM412T has two main outputs, with their type of connector as only difference:
electronically balanced screw terminal strips (18, 19) and unbalanced RCA connectors
(21).
Connection is made according to the following diagram:
In order to use a unbalanced output, you need to short pin 2 and pin 3, as indicated in the
previous diagram. Otherwise, the output signal won't have the right level and quality.
The mixer's main output level (OUTPUT VOL (7)) must be set in order to avoid your system
power amp clipping indicators (CLIP) to be permanently lit. Only the most powerful lower
frequencies must light them.
Other connections on the back panel:
REC output (17), 0dBV nominal, 10k.
L+R switch (20): convert output signals in a mono signal.
MUTE remote control input (22): external contact closure input. Allows connection
of fire detection systems or any other safety device that have to mute the mixer by
activating this control signal. The operating mode is internally selectable by
jumpers as "NO / NC" (normally open / normally closed).