Ecler MIMO88SG handleiding
Handleiding
Je bekijkt pagina 9 van 33

9
5.7. GPI Remote Control Ports
The rear panel of the MIMO SG offers 8 (MIMO88SG) or 12 (MIMO1212SG) GPI inputs
for 0-10 VDC continuous control voltage. Each of these inputs can be connected to an
external physical device (potentiometer, contact closure, continuously variable voltage 0-
10V DC, etc.) and assigned to a MIMO SG function, as for example:
• Input, output channel or matrix crosspoint volume remote control by means of a
WPaVOL physical knob or an Ecler WP Series’ WPVOL-IR remote control
• MUTE or SOLO activation/deactivation by means of a switch or contact closure
• Recalling a preset with a push button or contact closure
GPI connectors are screw terminal blocks with three-contacts. The wiring is as follows:
Positive, + 12 VDC > Pin +
Variable voltage, 0-12 VDC > Pin ↑
Ground > Pin ⊥
WPaVOL connection to MIMO serial GPI ports
WPaVOL-SR connection to MIMO serial GPI ports
Connecting cables can be up to 500 meters with a minimum section of 0.5 mm
2
.
Consult your ECLER dealer or www.ecler.com about the WP series remote control wall
panels and other accessories available for connection to the GPI port.
Jumpers position: ALOG / LIN
LIN position
+12 / +10 +12 position
Jumpers position: ALOG / LIN
LIN position
+12 / +10 +12 position
WPaVOL RJ45 pin 6 (+12VDC/+10VDC)
WPaVOL RJ45 pin 2 (Remote ZONE.)
WPaVOL RJ45 pin 1, 3 or 7 (GND)
WPaVOL-SR RJ45 pin 6 (+12VDC/+10VDC)
WPaVOL-SR RJ45 pin 2 (Remote VOL.)
WPaVOL-SR RJ45 pin 1, 3 or 7 (GND)
WPaVOL-SR RJ45 pin 8 (Remote VOL.)
WPaVOL-SR RJ45 pin 1, 3 or 7 (GND)