• Automatically: in case the initial message was SYSTEM CONNECT PINGPONG
and the client didn’t get any SYSTEM PONG message in a period longer than 10
seconds (presuming a communication breakdown).
The SET messages don’t have an automatic acknowledgement with a DATA message
sent from the EclerNet device after it has processed the SET command. The client must
update the values itself and must send the needed GET message if it requires
confirmation from the device.
NOTES:
• The numerical values are always integer numbers without +, –, comma or dot symbols.
• [PINGPONG] is an optional parameter used to configure the device-client
communication with a periodical check, to see whether the client or the device have
terminated it. When configured this way, the device sends a SYSTEM PING once per
second, and the client must answer with a SYSTEM PONG message. If anyone doesn’t
get these messages along a 10 seconds period, the communication will be considered
terminated.
• [ONCE] is an optional parameter used to start the device-client communication
without a full data dump process (usually a huge list of parameters & values).
• <Input Channel> & <Output Channel> are numerical values that identify an input or
output channel of the EclerNet device:
o It can be within a [1..8] range for MIMO88SG units.
o It can be within a [1..12] range for MIMO1212SG units.
• <Preset Number> is a numerical value that identifies one available Preset stored in the
EclerNet device’s memory.
• <Level>, <Pre Vumeter Level> y <Post Vumeter Level> are numerical values in the
[0..100] range that define values in a scale equivalent to [-inf..0] dB.
• <GPI> & <GPO> are numerical values within the [1..8] range for the MIMO88
configured as 8x8 matrix masters (single units), and [1..16] for MIMO88 couples
configured as 16x16 matrix masters. For the NXA series GPI values can be within the
[1..4] or [1..6] range, depending on model. For the MIMO7272DN and MIMO4040CDN
GPI and GPO values can be within [1..8].
• <GPI Value> is a numerical value within the [0..100] range that indicates the value of
an analogue GPI input. For a digital input only 0 or 100 are the possible values.
• <GPO Value> is a numerical value within the [0..1] range: it can only be 0 or 1 (opened
or closed GPO).
• <Rate> is a numerical value within the [1..10] range that sets the VU-meter refresh
rate, or the number of times the vumeters’ values are sent per second (by default = 3).
• “<Device Name>” is the device name inside double quotation marks, to allow for
names with blank spaces.
• <Error ID> is a numerical value for an error code.