TECHNICAL SPECIFICATIONS
Serial
Interface Type
Data Rate
Data Length
RS-232
RS-485/422
RS-232: 1200 - 115200 Kbps
RS-485/422: 1200 - 921600 Kbps
5,6,7,8 bits
Parity
Stop Bits
Flow Control
Connectors
Odd, Even, None
1-2bits
None
Software: Xon/Xoff,
Hardware: RTS/CTS
RS-232 DB-9 Male
RS-485 6-pin Euroblock
Network Interface
Interface type
Connector
Ethernet 10/100Mbps (Auto-Sensing)
8-pin RJ-45
System
CPU
Memory
Embedding RISC CPU 100Mhz
32KB SRAM.512KB Flash memory
Software
Network Protocols
TCP, UDP, DHCP Client, HTTP Server, DNS
Client, Telnet
Configure Options
Web page
LED Indicators
Link
TXD
RXD
PWR
10/100Base-TX Link & Activity Indicator
Data Transmitting from Eth to Serial Indicator
Data Receiving from Serial to Eth indicator
Power ON Indicator
Supply
DC Supply
Power Supply
9-24VDC
9VDC 1A
Mains (using supplied DC adapter)
100-240AC 50-60Hz