Step 4: Open Ecler Net Manager and create a UCP panel. Add a new control page and
add a new control button (Net String) as follow:
Write the following command:
|TCP|192.168.0.232|5000|SET MUTE ON\n| ***
Or
|TCP|192.168.0.232|5000|SET MUTE OFF\n| ***
This command will send the CA-NET command “SET MUTE ON” to the ETH232AD
interface (with 192.168.0.232 IP address and listening port 5000).
The ETH232AD interface will “translate” the TCP command as a RS-232 serial
command, allowing enabling or disabling the mute function on the amplifier. The red LED
on the CA amplifier will switch ON or OFF offering a rapid response about the correct
communication.
With the same philosophy it will be possible to control any other RS-232 third party
device.
*** Note: If the device belongs to batch G1005 the IP address will be 192.168.1.100