8.4.3 Conguration 3: Master connected to the internet via Wi-Fi, Nodes connected to Master
and each other in daisy-chain topology using RJ45 cable.
The maximum number of connected EV chargers in this configuration is 15. When creating a daisy-chain network using RJ45
cable, it is important to consider the locations of the Ethernet ports on the EV charger:
•
ETH0 (left port) of the Master should be connected to the ETH1 (right port) of Node 1.
•
ETH0 (left port) of Node 1 should be connected to the ETH1 (right port) of Node 2.
•
ETH0 (left port) of Node (n-1) should be connected to the ETH1 (right port) of Node (n).
Figure 58. Network diagram: Master connected via Wi-Fi, Nodes daisy-chained to Master and each other
8.4.3.1 Network connection settings: Master
Configuring the Master EV Charger includes setting up Wi-Fi and ETH0 port parameters. A qualified person
performing the installation should have a good understanding of IP network installation and commissioning.
To configure the Master EV charger, select the “Advanced” configuration first:
•
Go to the top of the configuration page (Figure 59).
•
Set “Configuration” to “Advanced” by selecting the option from the drop-down menu.
Figure 59. Selecting advanced configuration settings
82
GREEN MOTION BUILDING INSTALLATION MANUAL MN191028EN April 2024 www.eaton.com
Bekijk gratis de handleiding van Eaton Green Motion XCI000411, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Eaton |
| Model | Green Motion XCI000411 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 16416 MB |