Troubleshooting
Operating Instructions D888 e-con - 00.0 - 12/2023 227
8232 Error Stepper card parameter
initialization (Edge guide)
External Edge guide X Axis
Perform software update
Check selection of class
8251 Error Stepper card reference drive
timeout (Edge guide)
External Edge guide Y Axis
Check reference sensor
8258 Error Stepper card not responding
(Edge guide)
External Edge guide Y Axis
Perform software update
Replace the control
8259 Error Stepper card initialization
failure (Edge guide)
External Edge guide Y Axis
Perform software update
Check selection of class
8282 Error Stepper card parameter
initialization (Edge guide)
External Edge guide Y Axis
Perform software update
Check selection of class
9230 Warning No thread detected Check the thread
Check connection cables
Replace sensor
9240 Warning No thread tension sensor
detected (right)
Check sensor
Check connection cables
Replace thread tension sensor
9241 Warning No thread tension sensor
detected (left)
Check sensor
Check connection cables
Replace thread tension sensor
9300 Error CAN cable not connected Check CAN cable
Switch off the machine and disconnect all
CAN devices (including SSD!) from the
control, except for the lower machine
head PCB
Check if an error message other than
9300 is displayed
If an error message other than 9300 is dis-
played, switch off the machine, reconnect
another CAN device and check again
If error message 9300 is displayed again,
it is most likely that the device connected
last is faulty
Repeat the process until all devices are
connected again
Code Type Possible cause Corrective