Troubleshooting
Operating Instructions D888 e-con - 00.0 - 12/2023 205
10 Troubleshooting
10.1 Customer Service
Contact for repairs and issues with the machine:
Dürkopp Adler GmbH
Potsdamer Str. 190
33719 Bielefeld
Phone: +49 (0) 180 5 383 756
Fax: +49 (0) 521 925 2594
Email: service@duerkopp-adler.com
Internet: www.duerkopp-adler.com
10.2 Messages of the software
Code Type Possible cause Corrective
999 Error Error message • Software error
1000 Error Sewing motor encoder plug
X5B (Sub-D, 9-pin) not
connected
• Connect encoder cable to the control,
• use correct connection
1001 Error Sewing motor error
Sewing motor plug X2
(AMP) not connected
• Check connection and plug in
• Test sewing motor phases (R = 2.8Ω,
high impedance to PE)
• Replace encoder
• Replace sewing motor
• Replace the control
1002 Error Sewing motor insulation
error
• Check motor phase and PE for low-
impedance connection
• Replace encoder
• Replace sewing motor