Programming Commander DELTA
Operating Instructions D888 e-con - 00.0 - 12/2023 153
5.9.7.3 Parameters Thread tension sensor mode
Switch-off delay Value range
0 – 9999 [mm]
Seams
Input of the number of signal detections
after which the machine is supposed
to continue with the specifically set
parameters.
Value range
1 – 255
Filter stitches
Loosely woven fabric with stitches may
cause the light barrier to wrongly detect
a signal. To prevent this from happening,
you enter the number of filter stitches.
This number represents the minimum
number of stitches with signal detection
following the 1
st
detection of the signal.
Value range
0 – 255
Icon Menu item Setting
Lower limit Value range
0000 – 1100
Upper limit Value range
0000 – 1100
Thread tension warning delay stitches
If the specified maximum of allowed
faulty values is exceeded multiple times
in a row, the software outputs a warning.
Value range
000 – 100
Allowed faulty TT values per seam
If the specified maximum of allowed
faulty values is exceeded in the entire
seam, the software outputs a warning.
Value range
000 – 100
Icon Menu item Settings