Durkopp Adler D888 handleiding
Handleiding
Je bekijkt pagina 117 van 264

Programming Commander DELTA
Operating Instructions D888 e-con - 00.0 - 12/2023 115
5.7.6 Setting the Segment End parameters
There are various options for setting the Seam End parameters.
The following table lists all possible options.
Settings that are more complex and therefore require further
explanation are described in more detail after the table.
Height of sewing foot lift
Sewing stop
Value range
01 – 20 [mm]
(depending on subclass)
Light barrier
(optional additional equipment)
The light barrier detects the beginning
and the end of the material. After a signal
was detected, sewing can continue
automatically with the specifically set
parameters.
Value range
On/Off
( p. 152)
Thread tension sensor mode
(Access only after activation in the
machine configuration)
Value range
On/Off
( p. 153)
Icon Parameter Settings
Icon Parameter Settings
Parameters Seam End
Sewing foot lift after trim Value range
On/Off
Height of sewing foot lift after trim Value range
01 – 20 [mm]
(depending on subclass)
Thread trimmer Value range
On/Off
Bartack at seam end Value range
On/Off