Programming Commander DELTA
Operating Instructions D888 e-con - 00.0 - 12/2023 109
Setting options Sewing foot pressure
Menu item Setting 1 Setting 2
Linear
absolute
Sewing foot pressure
Value range
00–20
Maximum sewing foot
pressure reached at
the upper speed limit.
Min. Speed
Value range
0000 – 4000 [rpm]
(depending on subclass)
Speed at which the
increase in sewing foot
pressure should start.
Max. Speed
Value range
0000 – 4000 [rpm]
(depending on subclass)
Speed up to which the
increase in sewing foot
pressure should occur.
Linear
with
offset
Offset
Value range
-20–20
Difference up to maximum
sewing foot pressure
reached at the upper speed
limit.
Min.
Sewing speed
Value range
0000 – 4000 [rpm]
(depending on subclass)
Speed at which the
increase in sewing foot
pressure should start.
Max.
Sewing speed
Value range
0000 – 4000 [rpm]
(depending on subclass)
Speed up to which the
increase in sewing foot
pressure should occur.