Durkopp Adler D888 handleiding
Handleiding
Je bekijkt pagina 103 van 264

Programming Commander DELTA
Operating Instructions D888 e-con - 00.0 - 12/2023 101
5.7.3.2 Setting the Material thickness detection
parameters
To achieve consistently good sewing results for different material
thicknesses, some parameters can be adjusted specifically to the
material thickness.
Overview of setting modes
The material thickness can be identified in various modes and
responded to depending on the setting. This general explanation
can be applied to the following specific parameters.
Setting mode Description
Linear In the linear setting, the size of the parameter
increases or decreases steadily as the material
thickness increases. The increase/decrease of
the parameter depends on the limits set for the
minimum and the maximum material thickness.
2. Value
On/Off
If a certain material thickness is exceeded, the
second value of the parameter is activated. If the
material thickness then falls below this level again,
it switches to the base value for the parameter.
2. Value
On
If a certain material thickness is exceeded, the
second value of the parameter is activated. If the
material thickness then falls below this level again, it
does NOT switch to the base value for the parameter.
Only after finishing the seam by cutting the thread is
the base value for the parameter set again.