Durkopp Adler D867 e-con handleiding
Handleiding
Je bekijkt pagina 242 van 286

Troubleshooting
240 Operating Instructions D867 e-con - 00.0 - 06/2023
9352 Error Right thread tension pcb is
not connected
• Check connection cables
• Perform software update
• Replace PCB
9353 Information Needle thread tension sen-
sor pcb not connected
• Check connection cables
• Perform software update
• Replace thread tension sensor
9354 Error Needle Transport PCB not
connected
• Check connection cables
• Perform software update
• Replace needle transport PCB
9360 Error Edge guide pcb is not
connected
• Check connection cables
• Perform software update
• Replace PCB
9361 Error Edge guide x-axis pcb is not
connected
• Check connection cables
• Perform software update
• Replace PCB
9362 Error Edge guide y-axis pcb is not
connected
• Check connection cables
• Perform software update
• Replace PCB
9370 Warning Scanner module not
connected
• Check connection cables
• Perform software update
• Replace scanner module
9371 Warning Scanner module 24 V Error • Check connection cables
• Check connected scanners
• Replace scanner module
9372 Warning Scanner module 5 V Error • Stored analogue value for stroke
9910 Warning Sewing stop • Check tilt sensor on machine
• Check 24V
• Replace the control
9911 Warning Power down • The control is switched off
9912 Warning Restart necessary • Switch off the control
9913 Warning Empty bobbin • Please insert a full bobbin
9914 Warning Reset • Remove USB key!
9915 Warning Please Wait! • Please wait and do not remove USB key
Code Type Possible cause Corrective