Troubleshooting
Operating Instructions D867 e-con - 00.0 - 06/2023 239
9241 Warning No thread tension sensor
detected (left)
Check sensor
Check connection cables
Replace thread tension sensor
9300 Error CAN cable not connected Check CAN cable
Switch off the machine and disconnect all
CAN devices (including SSD!) from the
control, except for the lower machine
head PCB
Check if an error message other than
9300 is displayed
If an error message other than 9300 is dis-
played, switch off the machine, reconnect
another CAN device and check again
If error message 9300 is displayed again,
it is most likely that the device connected
last is faulty
Repeat the process until all devices are
connected again
9310 Error Tape feeder not connected Check connection cables
Perform software update
Replace the control of the tape feeder
9320 Error Tape feeder in lowered
position
Tape Feeder not in lowered position
9330 Information Material thickness sensor
not connected
Check connection cables
Perform software update
Replace material thickness sensor
9340 Information Remaining thread monitor
not connected
Check connection cables
Perform software update
Replace remaining thread monitor
9341 Information Bobbin control (left) not
connected
Check connection cables
Perform software update
Replace remaining thread monitor
9350 Error Upper machine head pcb is
not connected
Check connection cables
Perform software update
Replace PCB
9351 Error Lower machine head pcb is
not connected
Check connection cables
Perform software update
Replace PCB
Code Type Possible cause Corrective