Troubleshooting
Operating Instructions D867 e-con - 00.0 - 06/2023 237
8174 Error Stepper Puller Bottom init
position not found
Check for stiff movement
Replace encoder
Replace motor
8175 Error Stepper Puller Bottom not
enabled
Replace the control
8176 Error Stepper Puller Bottom
overload
Check for stiff movement
Replace encoder
Replace motor
8177 Error Stepper Puller Bottom
encoder failure
Connect encoder cable to the control:
Use correct connection
8178 Error Stepper Puller Bottom
Current sensor failure
Replace the control
8179 Error Stepper Puller Bottom
Incorrect stepping motor
direction of rotation
Replace encoder
Check if plugs have been mixed up
Check the wiring in the machine distribu-
tor and change it if necessary
8180 Error Stepper Puller Bottom refer-
ence drive failure
Check for stiff movement
Replace encoder
Replace motor
8181 Error Stepper Puller Bottom
overcurrent
Replace the control
8182 Error Stepper Puller Bottom
parameter initialization
Perform software update
Check selection of class
8183 Error Stepper Puller Bottom
insulation error
Check motor phase and PE for low-
impedance connection
Replace encoder
Replace motor
8185 Error Stepper Puller Bottom trans-
port interval failure
Perform software update
Check selection of class
8186 Error Stepper Puller Bottom refer-
ence drive failure
Check for stiff movement
Replace encoder
Replace motor
8201 Error Stepper card reference drive
timeout (Edge guide)
External Edge guide X Axis
Check reference sensor
Code Type Possible cause Corrective

Bekijk gratis de handleiding van Durkopp Adler D867 e-con, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.