Durkopp Adler D867 e-con handleiding
Handleiding
Je bekijkt pagina 229 van 286

Troubleshooting
Operating Instructions D867 e-con - 00.0 - 06/2023 227
2579 Error Stepper card X70 Current
sensor failure (Upper puller)
• Replace the control
2580 Error Stepper card X70 Incorrect
stepping motor direction of
rotation (Upper Puller)
• Replace encoder
• Check if plugs have been mixed up
• Check the wiring in the machine distribu-
tor and change it if necessary
2581 Error Stepper card X70 reference
drive failure (Upper puller)
• Check for stiff movement
• Replace encoder
• Replace motor
2583 Error Stepper card X70 overcurrent
(Upper puller)
• Replace the control
2584 Error Stepper card X70 parameter
initialization (Upper puller)
• Perform software update
• Check selection of class
2585 Error Stepper card X70 insulation
error (Upper puller)
• Check motor phase and PE for low-
impedance connection
• Replace encoder
• Replace sewing motor
2587 Error Stepper card X70 transport
interval failure (Upper puller)
• Perform software update
• Check selection of class
2588 Error Stepper card X70 reference
drive failure (Upper puller)
• Check for stiff movement
• Replace encoder
• Replace motor
2601 Error Stepper card X80 reference
run timeout (Bottom puller)
• Check reference sensor
2605 Error Stepper card X80 stepper
motor blockage (Bottom
puller)
• Check for stiff movement
2621 Error Stepper card X82 encoder
plug (Sub-D, 9-pin) not
connected (Bottom puller)
• Connect encoder cable to the control,
use correct connection
Code Type Possible cause Corrective