Durkopp Adler D867 e-con handleiding

286 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 158 van 286
Programming Commander DELTA
156 Operating Instructions D867 e-con - 00.0 - 06/2023
Edge Guide Check Up/Down Mode
To avoid collisions, an electronic prox-
imity switch checks the position of the
edge guide and keeps the edge guide
from moving.
(Access only after activation in the
machine configuration)
Value range
Off/Up/Down
(depending on the edge guide
position that is to be checked)
Light barrier
(optional additional equipment)
The light barrier detects the beginning
and the end of the material. After a sig-
nal was detected, sewing can continue
automatically with the specifically set
parameters.
Value range
On/Off
(see p. 158)
Switch foot stroke
alternation
Value range
On/Off
Thread tension sensor mode
(Access only after activation in
the machine configuration)
(see p. 159)
Seam Center Guide
(only on 2-needle machines, optional
additional equipment)
Value range
On/Off
Output
Segment Output 01-16 (see p. 159)
Icon Parameter Setting