Durkopp Adler D867 e-con handleiding
Handleiding
Je bekijkt pagina 109 van 286

Programming Commander DELTA
Operating Instructions D867 e-con - 00.0 - 06/2023 107
Setting options Sewing foot pressure
Menu item Setting 1 Setting 2
Linear
absolute
Sewing foot pressure
Value range 00 – 20
Maximum sewing foot pres-
sure reached at the upper
material thickness limit.
Min. material
thickness
Value range
00.0 – 10.0 [mm]
Material thickness at which
the increase in sewing foot
pressure should start.
Max. material
thickness
Value range
00.0 – 10.0 [mm]
Material thickness up to
which the increase in sew-
ing foot pressure should
occur.
Linear
with
offset
Offset
Value range -20 – 20
Difference up to maximum
sewing foot pressure
reached at the upper mate-
rial thickness limit.
Min. material
thickness
Value range
00.0 – 10.0 [mm]
Material thickness at which
the increase in sewing foot
pressure should start.
Max. material
thickness
Value range
00.0 – 10.0 [mm]
Material thickness up to
which the increase in sew-
ing foot pressure should
occur.