Programming Commander DELTA
Instructions for use 550-D869-100 e-con - 00.0 - 01/2025 93
Setting options Stitch length
Menu item Setting 1 Setting 2
Linear with offset Offset
Value range
-50–50 [%]
The current value of the
stitch length is increased/
decreased by the offset
value when the upper
material thickness limit has
been reached.
Min. material thickness
Value range
00.0–10.0 [mm]
Material thickness at which
the increase/reduction of
the stitch length should
start.
Max. material thickness
Value range
00.0–10.0 [mm]
Material thickness up to
which the increase/
reduction of the stitch
length should occur.
2. On/Off Min. material thickness
Value range
00.0–10.0 [mm]
Material thickness from
which the 2
nd
stitch length
should be used.
2. On Min. material thickness
Value range
00.0–10.0 [mm]
Material thickness from
which the 2
nd
stitch length
should be used.