Draper D20 98436 handleiding

11 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 9 van 11
9
6
FIG.
(12.1)
(12.2)
(12)
(11)
Caution: Only use the plug to disconnect from the
power supply, never use the cable.
Caution: If the battery charger has been in continuous
use it will be hot. Once charging is completed, leave the
charger to cool.
Only charge cooled batteries.
7.12 BATTERY PACK PROTECTION
FEATURES
Overcharging protection: When the battery pack is
fully charged, the transformer/charger will automatically
shuts off, protecting the internal components.
Over-discharging protection: Stops the battery pack
from discharging beyond the recommended lowest
safety voltage.
Overheating protection: An internal thermistor cut-off
sensor shuts off the battery pack should it become too
hot during operation. For example, if the tool is
overloaded or used for extended periods. 30 minutes
cooling time may be required.
Current protection: If the battery is overloaded or the
maximum current draw exceeded, the battery will shut
off to protect internal components. The battery pack will
resume operation once the current draw is at a safe
level.
Short circuit protection: The battery pack will stop
operating immediately if it was to short circuit.
7.13 BATTERY PACK CHARGE STATUS
– FIG.7
Press the charge level indicator button (11.2) to display
the battery charge level.
(11.2)
0 – 10% 0 – 25%
25 – 50%
50 – 75% 75 – 100%
7
FIG.
7.14 BATTERY LIFE EFFICIENCY AND
CHARGING ADVICE
Avoid recharging at high temperatures.
A rechargeable battery will be hot immediately after
use. If such a battery is recharged immediately after
use the battery life will be shortened. Leave the
battery and recharge it after it has cooled.
The battery should only be used and/or charged
when battery temperature is between 5°C and 30°C.
The battery needs to be warmed-up or cooled down
to prevent damaging to the batteries internal
components.
Note: If battery is too hot or too cold, allow it to
‘normalise’ before use or charging.
Note: Failure to warm up or cool down a battery could
result in serious damage to the battery, charger and
user.