Draper 28814 handleiding

20 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 14 van 20
– 14 –
9. OPERATION
9.4 FUSE REPLACEMENT – FIG.8
Ensure the unit is disconnected/switched off.
In the event of the fuse blowing, remove the
12V DC car cigarette lighter
12V DC battery connector leads (12) (model
28814 IN200/USB only).
Pull out the blown fuse (16) and replace with a
fuse of the same rating and design determining
the cause of the fault prior to re-using.
9.5 OPERATING TIPS
Resistive loads, such as incandescent lights, are
the easiest for the inverter to drive, though larger
resistive loads, such as electric stoves or heaters,
require more power than the inverter can deliver continuously.
Inductive loads, such as TV’s and stereos (any device with a coil or a transformer in it) require
more current to operate than a resistive load of the same power rating. Induction motors (motors
without brushes), as well as some televisions, may require 2 to 6 times their power rating to start
up. This condition may require the repeated on and off switching of the inverter power switch
several times in order to get them started.
The most demanding appliances are those that start under load, i.e. compressors and pumps.
Since motor and television characteristics vary widely, only experimentation will determine if a
specific load can be started and how long it can be run.
There are no standards for ‘surge power partly because it can not be simply represented by a
simple, single number. Though a 300W power inverter can provide power up to 600W for a short
period, experimentation is the only method of determining whether an inverter can handle the
surges generated by a particular load.
Important: The power inverter will not operate most appliances designed to produce heat, such
as hair dryers, coffee makers, irons, heaters, and toasters. The current use of most of these
exceeds rated power watts far beyond the capacity of these units. The inverter may be used either
while the engine is running or turned off, however, the inverter should not be operated while the
engine starting, since the battery voltage can drop substantially during cranking. The power
inverter draws less than 1.3 ampere from the battery when it is not supplying power to the load. In
most cases, the power inverter may be left connected to the battery when it is not in use, since it
draws so little current. If the vehicle will not be used for several days, disconnect the power
inverter from the battery.
8 FIG.