9. Maintenance and Troubleshooting
9.1 Manual Drainage
1. The unit will automatically stop when the tank is full.
Unplug before emptying the unit.
2. Move the unit carefully to avoid spilling the water.
3. Place a container for the water below the drain.
4. Remove the drain valve to allow the water to ow out
into the container.
Notes:
During drainage, tilt the body back slightly.
When the water has emptied, ret the drain valve.
Always ensure the drain valve is tted correctly
before restarting the unit.
9.2 Continuous Drainage
The self-evaporating system uses the collected water to
cool the condenser coils for more ecient performance.
There is no need to empty the drainage tank in cooling
mode as any condensation will evaporate and exit
through the exhaust outlet.
For continuous operation in dehumidifying mode,
connect the drain hose to the unit so that the water can
automatically ow into a bucket or drain.
1. Switch o the unit and remove the drain valve. Retain
in a safe place.
2. Securely connect the drainage hose (E), making sure
it is not kinked and clear of any obstructions.
3. Place the end of the hose over a drain or bucket so
the water ows freely out of the unit.
4. To prevent any air locks, do not submerge the end of
the hose completely in the water.
9.3 General Cleaning
• Always switch o and plug the unit before cleaning.
• Clean the outer surface of the unit with a soft damp
cloth and mild detergent. Wipe dry.
• Clean the air inlet and lter regularly to stop a build of
dust which can have a detrimental eect on the
performance of the unit.
• DO NOT operate the unit without the air lter tted.
9.4 Cleaning the Air Inlet Cover (4)
1. Lift o the air inlet mesh cover from the unit.
WARNING! To avoid injury to your ngers, do
not touch the evaporator surface when
removing the lter.
2. Use a soft brush or vacuum cleaner to remove any
dust or debris.
3. Ret to the unit.
9.5 Cleaning the Removable Air Filter (9)
1. Slide out the lter mesh from the unit.
2. Use a vacuum cleaner to suck dust and any debris
from the lter.
3. Turn the lter over and rinse the air lter under
running water.
4. Allow the lter to air dry completely before retting.