DWL-5x000XY DATA SHEET
Byte [n] Command Descriptions
Byte [0] 0x06 From computer
Byte [1] 0x01 To Sensor
Byte [2] 0x07 Alternate Zero in Single Axis Mode
Byte [3] 0x6C
Alternate Zero Command
0x6C: Set Alternate Zero
0x46: Reset Alternate Zero
Byte [4]~[9] 0x00 Not Applicable
Byte [10] 0x00 CRC16 High
Byte [11] 0x00 CRC16 Low
6.5.6. Alternate Zero in Dual Axis Mode
To set Alternate Zero in Dual Axis Mode:
<< (To sensor) : 0x06, 0x01, 0x0A, 0x6C, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00
Byte [n] Command Descriptions
Byte [0] 0x06 From computer
Byte [1] 0x01 To Sensor
Byte [2] 0x0A Alternate Zero in Dual Axis Mode
Byte [3] 0x6C Alternate Zero Command
0x6C: Set Alternate Zero
0x46 : Reset Alternate Zero
Byte [4]~[9] 0x00 Not Applicable
Byte [10] 0x00 CRC16 High
Byte [11] 0x00 CRC16 Low
After setting alternate zero, the sensor module will automatically switched to dual axis
mode. (Please refer to 6.5.2 Dual Axis Mode)
6.5.7. Absolute Level in Single & Dual Axis Mode Calculation
To set the device in absolute level measurement, please follow the following calculation formula:
Absolute offset data = (Front Measurement Position Value + Back Measurement Position Value) / 2
Absolute Level mode measurement = Measurement data - absolute offset data