Digi-Pas DWL5500XY handleiding
Handleiding
Je bekijkt pagina 47 van 73

Digi-Pas
®
© 2023 Digipas Technologies Inc. All Rights Reserved.
www.digipas.com
Page 41
DWL-5x000XY DATA SHEET
Byte [n] Command Descriptions
Byte [0] 0x61 To Computer / From Sensor
Byte [1] 0x1B Single Axis Position / Calibration Mode
Byte [2] 0x17 Calibration Feedback : Idle
Byte [3] 0x1E Calibration Count : 30
Byte [4] 0x13 Not Applicable
Byte [5] 0x02 Calibration Step 2 Ready
Byte [6] 0x88 Not Applicable
Byte [7]~[9] 0xDD Fixed Dummy
Byte [10] 0x22 CRC16 High
Byte [11] 0x93 CRC16 Low
6. Locate the sensor module as following Figure 36. The sensor is ready for user to perform
calibration step 2.
Figure 36. Tilt Sensor Module Position of Calibration Step 2
7. Repeat Step 4 to trigger the calibration step 2:
<< (To sensor): 0x06, 0x01, 0x0B, 0xB0, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00
8. Wait for response from the sensor. The sensor will broadcast the following response with
Byte 4 counting from 0x00 to 0x1E. Once Byte 4 counts to 0x1E, Byte 3 shows 0x17 from
0x0A and Byte 6 shows 0x03, calibration step 2 is completed. If Byte 3 from sensor response
is not equal to 0x17 and Byte 6 response is not equal to 0x03 after Byte 4 is counted to
0x1E, restart (power off and power on again) the sensor module and redo the calibration
process from the beginning (Step 1).
>> (From sensor): 0x61, 0x1B, 0x17, 0x1E, 0x13, 0x03, 0x88, 0xDD, 0xDD, 0xDD, 0x22, 0x93